| Voltage Rating |
3Φ480Vac(+10%,-15%) |
| Wiring |
3P+ N+ PE (Wye configuration) |
| Max. Input Current |
310A |
| Input Protection |
OVP, OPP, UVP, SPD, OCP, OTP |
| Max. Output Power |
DC 240 kW |
| Voltage Accuracy |
±2% |
| Current Accuracy |
±2% |
| Output Voltage Range |
200Vdc ~950Vdc |
| Maximum Output Current |
240A |
| Output Protection |
SCP, OCP, OVP, LVP OTP, IMD |
| Power Factor |
> 0.99 |
| Efficiency |
> 94%, at optimize V/I point |
| Cooling |
Natural Air or Liquid Cooling |
| Standby Power |
< 150W |
| Electrical Isolation |
Isolation between Input and Output |
| Internal Protection |
OTP, AC/DC contactor detection,
Fuse detection |
| Max. Connectors per Unit |
Dual |
| Supported Connector Types |
CCS1, J3400 NACS |
| Cable Lengths |
15 FT / 13 FT |
| Display |
21.5 Inch Media Touch Screen Display |
| Communication |
Ethernet, Wifi, 4G Cellular |
| Back-end Support |
OCPP 1.6 JSON, OCPP 2.0.1 |
| User Authentication |
RFID, QR Code, Mobile App,
Contact-less Credit Card Reader |
| Remote Load Management |
Via OCPP 1.6 JSON |
| Simultaneous Outputs |
100% - 0% Single / 50%-50% Dual |
| Safety |
UL2231 -1/-2, UL2202 |
| FCC Compliant |
YES |
| Ingress Protection |
IP55 NEMA 3R |
| Anti-Vandalism |
IK10, excluding LCD & RFID |
| Dedicated Breaker Rating |
400A |
| Operational Temperature |
-22°F - 122°F |
| Storage Temperature |
-40°F - 158°F |
| Relative Humidity |
MAX 95% RH, non-condensing |
| Altitude |
< 6,560 FT (2000m) |
| Dimensions |
35.2 x 26 x 86.6 Inches |
| Weight |
1102 lbs |